Typically, only 1ml of liquid in contact with the optical focal point will change the sensor's output. This enables early detection of caustic chemical spills and can be used to shut down the tool immediately, which minimizes the environmental impact.
HPQ-D11 | HPQ-D12 | |||
Supply Voltage | 12-24 VDC +/- 10% (Ripple 10% max) | 12-24 VDC +/- 10% (Ripple 10% max) | ||
Current Consumption | 30 milliamp max. | 30 miliamp max. | ||
Usable Pan | CPVC, Stainless Steel, etc. | CPVC, Stainless Steel, etc. | ||
Output Mode | NPN Transistor | PNP Transistor | ||
Output | Load Current 50 mA max (resistive load) Saturation Voltage 1V max. Short Circut, False Pulse, Reverse Polarity Protection | Load Current 50 mA max (resistive load) Saturation Voltage 1V max. Short Circut, False Pulse, Reverse Polarity Protection | ||
Light Source | Red LED (645 nm) | Red LED (645 nm) | ||
Indicator | Green ON: Normal Condition Orange ON: Liquid Detection | Green ON: Normal Condition Orange ON: Liquid Detection | ||
Operating Temperature | -25 to 50 Degree C | -25 to 50 Degree C | ||
Storage Temperature | -40 - 70 Degree C | -40 - 70 Degree C | ||
Sealing | IP67 (IEC Standard) | IP67 (IEC Standard) |
A large gain signal difference between no liquid and liquid detection ensures a low probability of false detection. The fail-safe design provides a normally closed output that turns off when liquid is detected.
Easily viewable green LED signifies normal operation and orange LED turns on when liquid is detected and output is shut off. The bracket assembly is made of CPVC material and has an over/under the patented style that assures solid retention once locked down and the ability to remove the sensor for maintenance or output checking. The underside of the bracket is flat and has perforated mounting holes so you can mount with hardware or adhesive.
Features of HPQ-D Series
- Body and cables are protected by PFA: PVC brackets are available for acidic or alkaline liquids. PFA (partially SUS) brackets are available for organic solvents.
- Easy maintenance: After leak detection, simply wipe the detector surface - a much easier process than with detection tape or a liquid absorbing model.
- Operation indicator: Switch status can be checked from the body side.
- Suitable for export equipment: CE marking, UL certified. Wide variety of output modes and types are available.